11 08, 2018

How to archive a TML project in EasyMotion Studio [GB]

2023-02-15T08:03:14+00:00

A project archive is a package which contains all the files necessary to use the TML project. When the archive is created, EasyMotion Studio will include apart from project file any other files required to run the TML project which are stored in various folders from EasyMotion Studio installation folder. Hence, a TML project can be correctly transferred from [...]

How to archive a TML project in EasyMotion Studio [GB]2023-02-15T08:03:14+00:00
11 08, 2018

The relationship between the speed resolution and the SLOW LOOP sampling period [II]

2018-09-09T16:35:55+00:00

In speed control, the speed resolution in case of an incremental encoder feedback depends on the encoder resolution and on the slow loop sampling period. The minimum speed that can be controlled (1 IU/sampling) can be computed using the following formula: Vmin [rpm] = 60 / (4 * Slow_Loop_period [s] * enc_lines * Tr) where: [...]

The relationship between the speed resolution and the SLOW LOOP sampling period [II]2018-09-09T16:35:55+00:00
11 08, 2018

How to restore an EasyMotion Studio project archive [GB]

2023-02-15T08:04:27+00:00

A TML project archive is a package which contains all the files required to use the project, archived in a ".m.zip" file. The file is saved by default in the Archives folder, from the EasyMotion Studio installation folder (by default C:\Program Files\Technosoft\ESM\Archives). The archive can be copied to a different location (another computer) and then restored. This [...]

How to restore an EasyMotion Studio project archive [GB]2023-02-15T08:04:27+00:00
11 08, 2018

Can I connect two motors in parallel? [GB]

2018-09-09T16:35:37+00:00

A Technosoft drive can control only one motor. Two motors cannot be controlled simultaneous (in parallel) because of the circulating currents (which cannot be controlled), thus decreasing the efficiency of the system, overheating the motor and making impossible to apply a stable control.

Can I connect two motors in parallel? [GB]2018-09-09T16:35:37+00:00
11 08, 2018

User variables defined in a TML program – [GB]

2023-02-15T08:08:24+00:00

The address of a user variables is automatically set in the order of declaration starting with 0x03B0 up to 0x03FF (80 words). First variable takes address 0x3B0, next one 0x3B1, etc. The user variables type can be: integer, fixed (point) or long (integer).     An int variable takes one memory location. A long or fixed variable takes 2 consecutive memory locations. In this case [...]

User variables defined in a TML program – [GB]2023-02-15T08:08:24+00:00
11 08, 2018

How to update the firmware of a Technosoft drive/motor [GB/CM]

2023-02-15T08:05:59+00:00

The firmware of a Technosoft drive/motor can be updated with the Firmware Programmer tool included in the EasyMotion Studio package. Remark: The firmware programming procedure can be executed only if the firmware present on the drive/motor is compatible with the one to be programmed. The compatibility between firmwares is verified by the Firmware Programmerbefore starting the programming procedure. Follow these steps [...]

How to update the firmware of a Technosoft drive/motor [GB/CM]2023-02-15T08:05:59+00:00